PERMABONDF201HV
High-strength anaerobic adhesive with resistance to peel, impact and fatigue forces. Intended for specified industrial bonding and sealing applications, including those covered by its hydrogen certification and potable-water listing.

Ideal For
Hydrogen PipeworkSpecified certified sealing applications.
Gas & Water FittingsMetal component retention and bonding.
Industrial Fluid SystemsAssemblies subject to thermal stress.
Technical Overview
| Technology | Anaerobic methacrylate |
|---|---|
| Appearance | Brown |
| Maximum gap fill | 0.3 mm |
| Maximum thread | M50 |
| Shear strength | 30 MPa (typical) |
| Handling strength | 15 min at 23°C* |
| Working strength | 1 hour at 23°C* |
| Full strength | 24 hours at 23°C* |
*Typical cure times on M10 steel; cure varies with substrate, gap and temperature. Potable-water use has separate requirements.
Key Features
- KIWA Inorm KE214 hydrogen certification
- WRAS listed for specified potable-water use
- High-strength toughened formulation
- Peel, impact and fatigue resistance
- Adhesion to aluminium and copper alloys
- Helps accommodate thermal stresses
- Suitable for close-fitting metal components
Application Overview

Clean surfaces and verify material compatibility and joint dimensions.

Apply adhesive and assemble components as directed in the current TDS.

Observe the required cure period before service, including potable-water conditions.
Gallery images are illustrative, not a step-by-step installation guide.
Downloads
PDFTechnical Data Sheet↓Request Further Documentation→Important Notes
- Not recommended for oxygen-rich systems or strong oxidising materials
- Check thermoplastic compatibility
- WRAS cure: 24 hours for brass, copper and cast iron at 21.1°C
- WRAS cure: 7 days for stainless steel and aluminium at 21.1°C
Need Technical Advice?
Ask our team about F201HV, certification scope, cure requirements and industrial applications.
ULTRABOND ADHESIVES